PEDJ

Fire Pump Set with Electric Diesel and Jockey Pump

TECHNICAL DESCRIPTION

* Switch Automatically among the three pumps

* Both Manual and Automatic operation is available

* Can work when the power is off

* Customized size and pump group

* YE3 high efficient motor with protection IP55 class F

* High performance and low power consumption

* Pump case with Anti-corrosive coating

* With NSK bearings, wear resistance mechanical seal

* Different Mounting Styles,Easy Installation

* Low Maintenance Cost and available spare parts

* Network of Technical Support

* ISO 9001 Manufacturing Facility

3D PRODUCT CHAT NOW

Related Products


Product Description


PEDJ Fire Pump System

(End Suction Electric Centrifugal Pump + End Suction Pump with Diesel Engine + Multistage Jockey Pump + Control Panel Box)

General Description for Fire Pump Set PEDJ

* PEDJ Fire Pump Set consists of End Suction Centrifugal Pump driven by Electric Motor, End Suction Diesel Pump, and Vertical Jockey Pump.

* Pumps are assembled with suction and discharge line accessories as well as Control Panel.

* Available Flow Capacities 50-1500GPM.

* Available Head/Pressure 1-14bar.

* Accessories include Suction pipe, Discharge pipe with Flanges, Battery, Gate Valves, Check Valves, Flexible Expansion Joints, Pressure Switches, Pressure Gauge,

Base Frame, etc.


Lifeguards for your safety
A Fire pump is an essential element for all highrise buildings. Fire pumps are also a necessity in warehouses and facilities that do not have adequate city water pressure.
With more than two decades of experience, we design, test and manufacture fire pumps to cater to diversified needs of our customers.

Our standard pumps can be manufactured in skid mounted units which are piped and wired. All the pumps are on a common base which also can be enclosed.

Our most comprehensive types of pumps used for fire service include end suction pump, horizontal split case pump and vertical pump models including stainless steel,
cast iron and bronze construction in standard configurations are provided by us. Close coupled frame mounted and engine drive options are also available.


APPLICATIONS

*  Fire Fighting System

*  Fire Hose Rack Systems

*  Fire Hose Reel Systems

*  Fire Foam Systems

*  Fire Deluge Systems

*  Fire Hydrant Systems

*  Fire Sprinkler Systems


USING LIMITS
Liquid temperature between -10℃ and +120℃
Ambient temperature up to +50℃
Max. working pressure 15 bar

Continuous service S1


PATENTS
Registered model PST

Registered Patent Design n° 201530478502.0


Main Pumps for Fire Pump Set PEDJ




Fire Pump Group Technical  Data and Quick Selection Table for Pump Models






Spare Parts

Production Line



Packaging & Shipping




Our Exhibition




Certifications




Related Products


Product Description


PEDJ Fire Pump System

(End Suction Electric Centrifugal Pump + End Suction Pump with Diesel Engine + Multistage Jockey Pump + Control Panel Box)

General Description for Fire Pump Set PEDJ

* PEDJ Fire Pump Set consists of End Suction Centrifugal Pump driven by Electric Motor, End Suction Diesel Pump, and Vertical Jockey Pump.

* Pumps are assembled with suction and discharge line accessories as well as Control Panel.

* Available Flow Capacities 50-1500GPM.

* Available Head/Pressure 1-14bar.

* Accessories include Suction pipe, Discharge pipe with Flanges, Battery, Gate Valves, Check Valves, Flexible Expansion Joints, Pressure Switches, Pressure Gauge,

Base Frame, etc.


Lifeguards for your safety
A Fire pump is an essential element for all highrise buildings. Fire pumps are also a necessity in warehouses and facilities that do not have adequate city water pressure.
With more than two decades of experience, we design, test and manufacture fire pumps to cater to diversified needs of our customers.

Our standard pumps can be manufactured in skid mounted units which are piped and wired. All the pumps are on a common base which also can be enclosed.

Our most comprehensive types of pumps used for fire service include end suction pump, horizontal split case pump and vertical pump models including stainless steel,
cast iron and bronze construction in standard configurations are provided by us. Close coupled frame mounted and engine drive options are also available.


APPLICATIONS

*  Fire Fighting System

*  Fire Hose Rack Systems

*  Fire Hose Reel Systems

*  Fire Foam Systems

*  Fire Deluge Systems

*  Fire Hydrant Systems

*  Fire Sprinkler Systems


USING LIMITS
Liquid temperature between -10℃ and +120℃
Ambient temperature up to +50℃
Max. working pressure 15 bar

Continuous service S1


PATENTS
Registered model PST

Registered Patent Design n° 201530478502.0


Main Pumps for Fire Pump Set PEDJ




Fire Pump Group Technical  Data and Quick Selection Table for Pump Models